Features:
  • Power supply:220V/50HZ
  • Normal operating conditions:Ambient temperature: 5 ℃ ~ 40℃; power supply voltage: 220V 22V power supply frequency: 50Hz  1Hz atmospheric pressure: 70KPa~106Kpa;
  • Longitudinal traction trip:0~200±10mm
  • Cervical traction trip:0~250±10mm
  • Swinging angle:±25°±2°
  • Angle angle:Upwards 10 ° ± 2 ° to 30 ° ± 2 °
  • Side angle:±20°±2°
  • Vertical traction:Continuously adjustable within the range of 10N~970N.
  • Cervical traction:Continuously adjustable within the 10N~294N.
  • Continuous traction time:Set in the 0~9min, the error is less than ± 30s
  • Intermittent traction:Set in the 0~90S, the error is less than ± 30s
  • Total traction time:Set in the 1~60min, the error is less than ± 30s
  • Traction speed:5~16 mm/s
  • Computer parameters: CPU speed≥1.5GHz clock≥ 2G, hard 120G, 1.5GHz, memory monitor ≥ 15 ″ LCD display
Features:
  • Power supply:220V/50HZ
  • Normal operating conditions:Ambient temperature: 5 ℃ ~ 40℃; power supply voltage: 220V 22V power supply frequency: 50Hz  1Hz atmospheric pressure: 70KPa~106Kpa;
  • Longitudinal traction trip:0~200±10mm
  • Cervical traction trip:0~250±10mm
  • Swinging angle:±25°±2°
  • Angle angle:Upwards 10 ° ± 2 ° to 30 ° ± 2 °
  • Vertical traction:Continuously adjustable within the range of 10N~970N.
  • Cervical traction:Continuously adjustable within the 10N~294N.
  • Continuous traction time:Set in the 0~9min, the error is less than ± 30s
  • Intermittent traction:Set in the 0~90S, the error is less than ± 30s
  • Total traction time:Set in the 1~60min, the error is less than ± 30s
  • Traction speed:5~16 mm/s
  • Computer parameters:CPU speed≥1.5GHz clock≥ 2G, hard 120G, 1.5GHz, memory monitor ≥ 15 ″ LCD display
Features:
  • Source: 220V/50Hz
  • Power: 360VA
  • Normal Operating conditions:
  • Environmental temperature:5℃~40℃
  • Supply voltage: AC220V±22V、50Hz±1Hz。
  • Atmospheric pressure:70.0kPa~106.0kPa
  • Drive distance for waist: 0~200±10mm
  • Drive distance for neck: 0~250±10mm
  • Rotation (swing angle): ±25°±2° adjustable
  • Angulation angle is from: -5±2° to 28°±2°,adjustable
  • Traction Force: 10N~970N adjustable
  • Neck Traction Force: 10N~294N adjustable
  • Constant traction time: 0~9 minutes,can be set freely, error is not more than ±30 S
  • Intermittent traction time: 0~90s ,can be set freely, error is not more than ±30 S
  • Total traction time: 1~60 minutes,can be set freely, error is not more than ±30 S
Features:
  • Source: 220V/50Hz
  • Power: 360VA
  • Normal Operating conditions:
  • Environmental temperature:5℃~40℃
  • Supply voltage: AC220V±22V、50Hz±1Hz。
  • Atmospheric pressure:70.0kPa~106.0kPa
  • Drive distance for waist: 0~200±10mm
  • Rotation (swing angle): ±25°±2° adjustable
  • Angulation angle is from: -5±2° to 28°±2°,adjustable
  • Traction Force: 10N~970N adjustable
  • Constant traction time: 0~9 minutes,can be set freely, error is not more than ±30 S
  • Intermittent traction time: 0~90s ,can be set freely, error is not more than ±30 S
  • Total traction time: 1~60 minutes,can be set freely, error is not more than ±30 S
Features:
  • Source: 220V/50Hz
  • Power: 240VA
  • Traction: waist 10~970N, neck 10-294N
  • Total setting time:1~60minutes
  • Setting time: 0~9minutes
  • Setting interval time:0~90second
  • Drive distance for waist:0~200mm
  • Drive distance for neck:0~250mm
  • Cube: L2600×W700×H9300mm